St-536 groove cleaning agent instruction

2022-03-02 314

IProduct overview

In the development production of circuit board, the residue of dry film or green paint is easy to accumulate on the roller and groove wall with the passage of time. In subsequent production, it is easy to stick back on the plate surface and cause open circuit or connection. It is difficult to remove it with traditional alkali washing or pickling and commercial double liquid groove cleaning agent,ST-536#The single dosage tank cleaning agent can clean the green paint or dry film through the combined action of dissolution and stripping, without any damage to the roller and tank wall.

IIProduct nature

appearance: Light brown liquid

Specific gravity: 1.1-1.3

PH value: < 2

Odor: Slightly pungent

IIIOperating conditions

Temperature:45-fifty℃

Concentration:15-20% (volume ratio)

Ventilation: required

IVMain components and functions

1. Organic acid can remove metal precipitation ions in dirt, and can properly dissolve part of grease and dry film.

2. Organic solvent: dissolve grease and dry film.

3. Surfactant: accelerate the dissolution and decomposition of oil.

VOperation method

1. Drain the developer completely;

2. Inject tap water to the liquid level and discharge after circulating for 10 minutes;

3. Infuse2/3Tap water, turn on heating, cover all covers and turn on air extraction.

4. According to the volume ratio of liquid medicine to tap water 20%(subject to pollution) addST-536#Single dosage of tank cleaning agent, open the circulation after covering the cover plate. Wait until the temperature rises toDischarge after circulating for 1 hour after 40-45 ℃ (depending on the pollution).

5. At the same time, wash the roller and the groove wall of the developing cylinder with high-pressure water to clean the residual liquid.

6. Neutralize with 3-5% NaOH for 30 minutes, then discharge and wash.

7. Add developer and start normal development.

6、 Other precautions:

1. When operating single dosage tank cleaning agent, you must wear labor protection articles.

2. Temperature is one of the important factors for good cleaning effect; Good sealing can avoid the overflow of pungent odor, and good ventilation is very necessary.

3. For the roller with serious pollution in the front stage of outer dry film development, it can be removed and soaked in the stock solution and heated tofifty℃,sixtyTake it out and wash it in minutes.

4. Where the wall of the developing tank is seriously polluted, it can be directly wiped with a rag dipped in the liquid medicine stock solution to swell the caked and hardened ink pollutants before cleaning;

5. If the ink or film residue is too thick, it must be cleaned2-3And increase the concentration for times before it can be thoroughly cleaned.

6. If the liquid medicine splashes on the skin, please wash it with a large amount of tap water immediately, and wash it with dilute soap solution before going to the doctor. If it splashes on the eyes, please wash it with a large amount of water and go to the doctor immediately.

7、 Store

This product should be stored in a ventilated and cool place to avoid direct sunlight, open fire source and stacking with strong alkali or strong reductant materials. The stacking height should not exceed two layers.